PLATEC Electroless Nickel CN-857 / M / A / B / C / D

Product features:

Excellent starting ability and good plating solution stability.
Applicable to all kinds of solder mask.
Adding machine with the automatic analysis of nickel, have stable solution and labor-saving.
Phosphorus content: 5~8 %.

Reliability Tests:

ITEM REFERENCE DOCUMENT RESULT
1 SALT SPRAY TEST MIL-STD-883G Method 1009.8 specification.
Duration of test:96hours
PASS
2 TEMPERATURE CYCLING TEST Temperature range:-65°C~ +125°C
Number of cycles:100cycles
PASS
3 TEMPERATURE AND HUMIDITY STORAGE TEST Temperature:65°C Humidity:95% RH
Test Time:168hours
PASS
Focused Ion Beam, FIB
Scanning Electron Microscope, SEM